Data Model

Design principles

  • components are metadata-driven
  • placement data is separate from catalog data
  • plugin-imported components must behave like built-in components
  • cable links are first-class entities

Core entities

RackTemplate

Describes a rack type that can be instantiated in projects.

Suggested fields:

  • id
  • name
  • rack_standard as 10_inch or 19_inch
  • total_u
  • usable_depth_mm
  • max_weight_kg
  • mounting_style

Project

  • id
  • name
  • owner_id
  • created_at
  • updated_at
  • status

RackInstance

  • id
  • project_id
  • rack_template_id
  • label
  • position_index

ComponentDefinition

Catalog entry for a reusable part.

  • id
  • source_type as builtin or plugin
  • plugin_id
  • manufacturer
  • part_number
  • name
  • category
  • rack_standard
  • height_u
  • width_mm
  • depth_mm
  • weight_kg
  • power_w
  • price_net
  • currency
  • front_svg_asset_id
  • preview_3d_asset_id

ComponentInstance

Placed component inside a rack.

  • id
  • project_id
  • rack_instance_id
  • component_definition_id
  • start_u
  • orientation
  • notes

PortDefinition

Optional port model for cable planning.

  • id
  • component_definition_id
  • name
  • side as front or rear
  • offset_x_mm
  • offset_y_mm
  • offset_z_mm
  • port_type
  • id
  • project_id
  • from_component_instance_id
  • from_port_definition_id
  • to_component_instance_id
  • to_port_definition_id
  • cable_type
  • estimated_length_mm
  • slack_percent
  • manual_override_length_mm

PluginPack

  • id
  • name
  • version
  • vendor
  • manifest_version
  • status
  • imported_at

Validation rules

  • ComponentDefinition.rack_standard must match RackTemplate.rack_standard
  • ComponentInstance.start_u plus height_u must not exceed rack height
  • placed components must not overlap
  • cable links should only reference valid ports belonging to the selected components

BOM generation logic

The BOM should aggregate by:

  • manufacturer
  • part_number
  • optional variant attributes such as color or length

The BOM should be able to combine:

  • placed components
  • accessory parts
  • calculated cables

Future extensions

  • multi-rack room coordinates
  • thermal zones
  • separate front and rear accessories
  • stock and supplier integration